WE ARE COMMITTED TO REPORTING THE LATEST FORESTRY ACADEMIC ACHIEVEMENTS

Volume 34 Issue 2
Nov.  2019
Article Contents
Turn off MathJax

XIE Jin-hua, YANG Xiao-rong, CAO Xia, HU Liu-ping. A Study of the Method of Rapid Determination of Urea Solution Concentration by Baume' Hydrometer[J]. Journal of Sichuan Forestry Science and Technology, 2013, 34(2): 69-73. doi: 10.16779/j.cnki.1003-5508.2013.02.016
Citation: XIE Jin-hua, YANG Xiao-rong, CAO Xia, HU Liu-ping. A Study of the Method of Rapid Determination of Urea Solution Concentration by Baume' Hydrometer[J]. Journal of Sichuan Forestry Science and Technology, 2013, 34(2): 69-73. doi: 10.16779/j.cnki.1003-5508.2013.02.016

A Study of the Method of Rapid Determination of Urea Solution Concentration by Baume' Hydrometer


doi: 10.16779/j.cnki.1003-5508.2013.02.016
More Information
  • Received Date: 2012-12-09
  • Based on establishing the urea solution concentration, Baume degree sequence value table of different temperature, and getting the Baume' degree sequence value of different urea solution by Baume' hydrometer, the urea solution concentration can be achieved by Baume' degree sequence value table. By means of this method, the accuracy was more than 89.95% as compared with Kjeldahl method, thus being able to offer reference for further improving the method of rapid determination of urea solution concentration. This method was easy to operate with less reagent consumption, high accuracy and rapid speed.
  • 加载中
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(253) PDF downloads(2) Cited by()

Related
Proportional views

A Study of the Method of Rapid Determination of Urea Solution Concentration by Baume' Hydrometer

doi: 10.16779/j.cnki.1003-5508.2013.02.016
  • Sichuan Academy of Forestry, Chengdu 610081, China

Abstract: Based on establishing the urea solution concentration, Baume degree sequence value table of different temperature, and getting the Baume' degree sequence value of different urea solution by Baume' hydrometer, the urea solution concentration can be achieved by Baume' degree sequence value table. By means of this method, the accuracy was more than 89.95% as compared with Kjeldahl method, thus being able to offer reference for further improving the method of rapid determination of urea solution concentration. This method was easy to operate with less reagent consumption, high accuracy and rapid speed.